(0255) 6 28 28 28

LOW TEMPERATURE CURE INJECTABLE VINYLESTER RESIN

X2000 380ML

Cold weather concrete block anchor resin

X2000 is the solution for cold weather adhesive anchoring applications in uncracked concrete. Fast curing is the feature of Vinyl ester. Save time to achieve high bonding strength. No styrene and VOC approval qualified for environmentally friendly and green house. Excellent in acid-resisting, alkali-resisting for chemical industry installation.

A two-component 10:1 resin chemical anchoring injection system. Convenient setting and fast curing in low temperature. All of our products had tested and approved in Germany according to EAD 330499-00-0601. Vinylester anchor mortar is available for fixings on non-cracked concrete, masonry, brick, stone, perforated brick. There are also 150ml, 235ml, 345ml and 360ml for diverse market preference.

Chemical fixing system – Fast curing viny lester chemical anchor

The obvious characteristic of vinylester hybrid mortar is fast curing to save installation time and hardening time. We develop diverse curing time to meet different country weather and installation temperature. Fast curing formula is not suitable for nonstandard high temperature which caused curing time accelerated. Please check technical data sheet for safety installation.

Specification of X2000 vinylester chemical anchor

  • Material: Vinylester Styrene Free
  • Model Number: X2000
  • Size: 380ml
  • Shelf Life: 18 months
  • Mixing Ratio: 10:1
  • Mixed Color: Gray
  • Standard Package: One cartridge with one mixer
  • Other Accessory: Mixer, caulking gun, nylon sleeve, air pump, brush

Vinylester chemical anchor provide excellent bonding strength in cold weather

  • Suitable for cold weather application
  • Provide maximum flexibility and efficiency
  • Fast curing time
  • Styrene free and low odor with VOC certificate
  • Excellent acid and alkali resistance
  • ECO friendly building material

                   

Winter version vinylester injection hybrid styrene free adhesive

X2000 winter version is developed principally to low temperature anchoring. It still provides fast curing time and high bonding strength for threaded stud bolts and rods. For applied to solid elements, such like concrete, stone, cement, and wood. It’s very good chemical resistance to acid and alkali environment. In 10-20℃ working place, the gelling time is 5min and full curing time is 35min.

         

Technical Data

CHART 1. SOLID SUBSTRATE REBAR INSTALLATION DETAILS

Pressure Destroy Haul Strength
(Kgf/KN)
Safety Haul Strength
(Kgf/KN)
Working Standard
(mm)
Concrete Strength 4,000 psi 280 kg/cm2 4,000 psi 280 kg/cm2 Hole Diameter Hole Depth
Rebar No. #3 (Φ10) 3,540 35.8 1,180 11.9 13 90
#4 (Φ13) 5,490 55.4 1,827 18.5 16 120
#5 (Φ16) 9,060 91.5 3,020 30.5 20 145
#6 (Φ19) 14,150 142.9 4,717 47.6 25 170
#7 (Φ22) 18,630 188.2 6,210 62.7 28 200
#8 (Φ25) 23,195 234.3 7,732 78.1 32 225
#9 (Φ29) 25,340 256.0 8,447 85.3 37 250
#10 (Φ32) 32,120 324.4 10,707 108.1 40 290
Remarks: 1. Concrete Strength fc’: 280kg/cm2 (4,000 psi)
2. Rebar Strength: #3~#5 fy: 2,800 kgf/cm2, #6~#11 fy= 4,200 kgf/cm2

CHART 2. CURING TIME TABLE

Cartridge temperature (Mortar) Gelling time Temperature at anchoring base
Curing time
-15℃ – -10℃ 15 hours.
-10℃ – -5℃ 10 hours.
-5℃ – ±0℃ 15 min. -5℃ – ±0℃ 4 hours.
-±0℃ – +5℃ 10 min. -±0℃ – +5℃ 1 hour 40 min.
+5℃ – +10℃ 6 min. +5℃ – +10℃ 50 min.
+10℃ – +20℃ 5 min. +10℃ – +20℃ 35 min.
Remarks:

1. Without approval
2. The above times apply from the moment of contact between resin and hardener in the static mixer.
For installation, the cartridge temperature must be at least +5℃. For longer installation times, when interruptions occur in work, the mixer should be replaced.
3. Pull out testing should be implemented after 24hours.

CHART 3. FIXING CONSUMPTION PER CARTRIDGE

Anchor Size Hole Diameter
(mm)
Hole Depth
(mm)
Number of Fixings
235ml 280ml 345ml 360ml 380ml
M8 10 80 47 56 69 72 76
M10 12 90 29 34 42 44 47
M12 14 110 17 21 25 27 28
M16 18 125 9 11 14 14 15
M20 24 170 4 5 6 6 6
M24 28 210 2 3 3 4 4
M30 35 270 1 1 2 2 2
M36 40 330 1 1 1 1 1
Note: Based on continuous installation without interruptions or nozzle changes. Provided as a guide and will vary with temperature.

How to install chemical anchor?

1. Drill the specific hole size and depth. 2. Clean dust with brush and air blow pump. 3. Press out unmixed resin which can’t be used. 4. Inject mixed resin into drilled hole and fill from the bottom. 5. Insert rebar/threaded rod/steel strip. Curing time refer to TDS. Don’t touch until full curing. The installation process will affect the bonding performance of chemical anchors.